Graffunder Bishop Series

Due to the nature of their applications and our philosophy of randomization, the following unit is highly customizable and tailored to the individual end user.

Door

Outer plate - Minimum 1/2" of high tensile steel, 3-1/2" overall thickness. The door contains 1-1/2" U.L. approved fire insulating material. High temperature heat seals and smoke seals are incorporated in strategic areas.

Anti-drill barriers - Hardened steel ball bearing plates.

Lock - U.L. listed group 2 mechanical lock.

Re-locking systems - Randomly positioned, independent live re-lockers, thermally and mechanically activated.

Door Bolts - 1-1/4" diameter solid stainless steel.

Body

Outer plates consisting of minimum 1/4" high tensile steel. Built with additional barrier of 1-1/2" proprietary high density, cement based composite material, enclosed between outer plate and 14 or 16 gauge interior steel body.

Standard Model Includes:

  • Texture paint.
  • Three-spoke handle.
  • Group 2 U.L. listed mechanical lock.
  • Electrical access hole.
  • Bolt down hole.
  • Choice of interior #1, #3, or #5.

Custom Options - Discuss with your distributor.

Graffunder Castle Series

Due to the nature of their applications and our philosophy of randomization, the following unit is highly customizable and tailored to the individual end user.

Door

Outer plate - Minimum 1" of high tensile steel, 4" overall thickness. The door contains 1-1/2" U.L. approved fire insulating material. High temperature heat seals and smoke seats are incorporated in strategic areas.

Anti-drill barriers - Hardened steel ball bearing plates.

Lock - U.L. listed group 2 mechanical lock.

Re-locking systems - Randomly positioned, independent live re-lockers, thermally and mechanically activated.

Door Bolts - 1-1 /4" diameter solid stainless steel.

Body

Outer plates consisting of minimum 1/2" high tensile steel. Built with additional barrier of 1-1/2" proprietary high density, cement based composite material, enclosed between outer plate and 14 or 16 gauge interior steel body.

Standard Model Includes

  • Texture paint.
  • Three-spoke handle.
  • Group 2 U.L. listed mechanical lock.
  • Electrical access hole.
  • Bolt down hole.
  • Choice of interior #1, #3, or #5.

Custom Options - Discuss with your distributor.

Graffunder Emperor Series

Due to the nature of their applications and our philosophy of randomization, the following unit is highly customizable and tailored to the individual end user.

Door

Outer plate - Minimum 1-1/2" of high tensile steel, 4-1/2" overall thickness. The door contains 1-1/2" U.L. approved fire insulating material. High temperature heat seals and smoke seals are incorporated in strategic areas.

Anti-drill barriers - Hardened steel ball bearing plates.

Lock - U.L. listed group 2M mechanical lock.

Re-locking systems - Randomly positioned, independent live re-lockers, thermally and mechanically activated.

Door Bolts - 1-1/4" diameter solid stainless steel.

Body

Outer plates consisting of minimum 1" high tensile steel. Built with additional barrier of 1-1/2" proprietary high density, cement based composite material, enclosed between outer plate and 14 or 16 gauge interior steel body. (TL-15 Equivalent)

Standard Model Includes:

  • Texture paint.
  • Three-spoke handle.
  • Group 2M U.L. listed mechanical lock.
  • Electrical access hole.
  • Bolt down hole.
  • Choice of interior #1, #3 or #5.

Custom Options - Discuss with your distributor.

Graffunder Fortress Series

Due to the nature of their applications and our philosophy of randomization, the following unit is highly customizable and tailored to the individual end user.

Door

Outer plate - Minimum 1-1/2" lamination of 1" high tensile steel and 1/2" manganese plate 4-1/2" overall thickness. The door contains 1-1/2" U.L. approved fire insulating material. High temperature heat seals and smoke seals are incorporated in strategic areas.

Anti-drill barriers:

  • Mangalloy plate protects locking bolt work from punch attack.
  • Carbide chip plate.
  • Deflector plates.

Lock - Choice of U.L. listed group 2M mechanical lock or electronic lock.

Re-locking systems - Randomly positioned, independent live re-lockers, thermally and mechanically activated.

Door Bolts - 1-1/4" diameter solid stainless steel.

Body

Punch-resistant bolt work. Outer plates consisting of minimum 1" high tensile steel. Built with additional barrier of 1-1/2" proprietary high density, cement based composite material, enclosed between outer plate and 16 gauge interior steel body. (TL-30 Equivalent)

Standard Model Includes:

  • Texture paint.
  • Three-spoke handle.
  • Group 2M U.L. listed mechanical lock or electronic lock.
  • Electrical access hole.
  • Bolt down hole.
  • Choice of interior #1, #3, or #5.

Custom Options - Discuss with your distributor.